800-171 Evidence

November 05, 2026

Airbyte Connector Builder Flaw: Access and Remediation Evidence

Airbyte Connector Builder access diagram

National Institute of Standards and Technology (NIST) 800-171 asks teams to limit access and fix flaws on time. A data tool flaw tests both asks at once.

The access problem

Connector Builder runs declarative manifests that describe a data connector. Before 2.2.0, it did not limit which Python classes a manifest could call. A user with Workspace Reader access or higher could run commands in the container. That is a low level of access for that much power. The flaw worked even when unsafe code was turned off. Airbyte 1.x with the legacy Helm chart is worse. There, any client with network access could exploit it without logging in.

What to file

First, the Airbyte version on each deployment. Second, the upgrade date to 2.2.0 or later. Third, the access list for each workspace, with Reader access named. Fourth, the network limits on the Connector Builder service. Fifth, the credential rotation for secrets the container could reach. File one record per deployment. A single note that says upgraded is not enough.

PolicyCortex does not upgrade data tools. PolicyCortex helps teams link proof to requirements.

Sources

  • Airbyte security advisory GHSA-g35w-6r6v-h4r7. https://github.com/airbytehq/airbyte/security/advisories/GHSA-g35w-6r6v-h4r7
  • JPCERT/CC advisory JVN12040144, November 4, 2026. https://jvn.jp/en/jp/JVN12040144/
  • SecurityOnline coverage, November 4, 2026. https://securityonline.info/airbyte-vulnerability-exploited/
  • Original diagram by PolicyCortex

Next step

File one record per Airbyte deployment, with the version, the upgrade date, and the access list.